| Home | Aufgabenstellung | Pflichtenheft | Implementierung | Spezifikation | Dokumentation |
Implementierung |
|||||
---------------------------------------------------------------------------------------------------
--
-- Title : converter
-- Design : Converter
-- Author : Ferdi
-- Company : TUM
--
---------------------------------------------------------------------------------------------------
--
-- File : converter.vhd
-- Generated : Sun Feb 6 12:57:27 2005
-- From : interface description file
-- By : Itf2Vhdl ver. 1.20
--
---------------------------------------------------------------------------------------------------
--
-- Description : Parallel/Seriell Converter
--
---------------------------------------------------------------------------------------------------
library IEEE;
use IEEE.STD_LOGIC_1164.all;
use IEEE.std_logic_unsigned.all;
entity converter is
port (
Reset : in STD_LOGIC; -- Asynchroner Reset
FSYNC : in STD_LOGIC; -- Worttakt
SCLK : in STD_LOGIC; -- Bittakt
MONO : in STD_LOGIC_VECTOR(0 to 15); -- 16 Bit Mono Signal
READY : in STD_LOGIC; -- Ready Signal
FSYNC_OUT : out STD_LOGIC; -- Worttakt
SDATA_OUT : out STD_LOGIC; -- Bittakt
SCLK_OUT : out STD_LOGIC; -- Serielles Datum
);
end converter;
architecture converter of converter is
-- interne Signale
signal OLD_FSYNC : STD_LOGIC;
signal M_1 : STD_LOGIC_VECTOR(0 to 15);
signal M_2 : STD_LOGIC_VECTOR(0 to 15);
signal S : INTEGER; -- Zustände
signal Z_B : INTEGER; -- Zähler Bit
signal Z_D : INTEGER; -- Zähler Durchgang
signal Z_M : INTEGER; -- Zähler geladene MONO Signale
begin
system_mode: process (SCLK, Reset, FSYNC, M_1, M_2, Z_B, Z_D, Z_M, OLD_FSYNC, S)
begin
if (Reset = '1') then
M_1 <= "0000000000000000";
M_2 <= "0000000000000000";
S <= 0; -- Ein asynchroner Reset ist aufgetreten, dann
Z_B <= 0; -- werden alle fuer diesen Prozess relevanten
Z_D <= 0; -- Signale in den Initialzustand zurueckgesetzt.
Z_M <= 0; -- Ansonsten, bei jeder steigenden Taktflanke,
elsif (SCLK'event and SCLK = '1') then
if (S = 0 and READY = '1') then
M_1 <= MONO;
Z_M <= 1;
Z_D <= 1;
Z_B <= 15;
S <= 1;
end if;
if ( S = 1 and FSYNC = OLD_FSYNC) then
S <= 1;
end if;
if (S = 1 and FSYNC /= OLD_FSYNC) then
FSYNC_OUT <= FSYNC;
SDATA_OUT <= M_1(15);
Z_B <= Z_B-1;
S <= 2;
end if;
if (S >= 2 and S <=(15)) then
FSYNC_OUT <= FSYNC;
SDATA_OUT <= M_1(Z_B);
Z_B <= Z_B-1;
if (READY = '1') then
M_2 <= MONO;
Z_M <= 2;
end if;
S <= S+1;
end if;
if (S = (16) and Z_D = 1) then
FSYNC_OUT <= FSYNC;
Z_B <= (15);
Z_D <= 2;
SDATA_OUT <= M_1(0);
S <= 1;
end if;
if (S = (16) and Z_M = 2) then
SDATA_OUT <= M_1(0);
M_1 <= M_2;
Z_D <= 1;
Z_B <= (15);
S <= 1;
end if;
if (S = (16) and READY = '1') then
SDATA_OUT <= M_1(0);
M_1 <= MONO;
Z_D <= 1;
Z_M <= 1;
Z_B <= (15);
S <= 1;
end if;
if (S = (16) and Z_D = 2 and Z_M = 1and READY = '0') then
S <= 0;
end if;
SCLK_OUT <= SCLK;
OLD_FSYNC <= FSYNC;
end if;
end process system_mode;
end converter;